Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 32(4): 6520-6530, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38439352

RESUMO

Frequency conversion in glass optical fibers requires both phase and group velocity matching between the pump and the higher harmonic when working with short pulses. We show that phase and group velocities can be matched simultaneously for third order nonlinear processes, by considering that the third harmonic propagates in the higher order azimuthally symmetric LP03-mode. Moreover, the pump and frequency tripled signals can form an intermodal two-color pump to trigger a cascaded wave mixing process, which generates the second harmonic LP01-mode. This opens avenues for second harmonic generation without need for a second order nonlinearity in the optical fiber.

2.
Biosens Bioelectron ; 255: 116237, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38537429

RESUMO

Scintillation-based fiber dosimeters are a powerful tool for minimally invasive localized real-time monitoring of the dose rate during Low Dose Rate (LDR) and High Dose Rate (HDR) brachytherapy (BT). This paper presents the design, fabrication, and characterization of such dosimeters, consisting of scintillating sensor tips attached to polymer optical fiber (POF). The sensor tips consist of inorganic scintillators, i.e. Gd2O2S:Tb for LDR-BT, and Y2O3:Eu+4YVO4:Eu for HDR-BT, dispersed in a polymer host. The shape and size of the tips are optimized using non-sequential ray tracing simulations towards maximizing the collection and coupling of the scintillation signal into the POF. They are then manufactured by means of a custom moulding process implemented on a commercial hot embossing machine, paving the way towards series production. Dosimetry experiments in water phantoms show that both the HDR-BT and LDR-BT sensors feature good consistency in the magnitude of the average photon count rate and that the photon count rate signal is not significantly affected by variations in sensor tip composition and geometry. Whilst individual calibration remains necessary, the proposed dosimeters show great potential for in-vivo dosimetry for brachytherapy.


Assuntos
Técnicas Biossensoriais , Braquiterapia , Dosímetros de Radiação , Fibras Ópticas , Polímeros
3.
Sensors (Basel) ; 22(21)2022 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-36365926

RESUMO

Wide field-of-view imaging optics offer a huge potential for space-based Earth observation enabling the capture of global data. Reflective imaging telescopes are often favored, as they do not show chromatic aberrations and are less susceptible to radiation darkening than their refractive counterparts. However, the main drawback of reflective telescopes is that they are limited with respect to field-of-view while featuring large dimensions. We propose the use of freeform optics to maximize the field of view while maintaining diffraction-limited image quality and minimizing system dimensions. In this paper, we present a novel freeform wide field-of-view reflective telescope, starting from the optical design, and continuing to tolerancing analysis and manufacture, towards a proof-of-concept demonstrator. The novel telescope features a full field-of-view of 120° while showing an exceptional spatial resolution of 2.6 km and fitting within 1 CubeSat unit. To the best of our knowledge, this is the widest field-of-view that has ever been realized for a space-based telescope, nearly reaching Earth observation from limb to limb from an altitude of about 700 km. We hope this design paves the way for future space missions enabling improved Earth observation and leading to enhanced monitoring of climate and climate change.

4.
Opt Express ; 30(11): 19961-19973, 2022 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-36221758

RESUMO

We demonstrate distributed optical fiber-based pressure measurements with sub-bar pressure resolution and 1 m spatial resolution over a ∼100 m distance using a phase-sensitive optical time-domain reflectometry technique. To do so, we have designed a novel highly birefringent microstructured optical fiber that features a high pressure to temperature sensitivity ratio, a high birefringence and a mode field diameter that is comparable to that of conventional step-index single mode fibers. Our experiments with two fibers fabricated according to the design confirm the high polarimetric pressure sensitivities (-62.4 rad×MPa-1×m-1 and -40.1 rad×MPa-1×m-1) and simultaneously low polarimetric temperature sensitivities (0.09 rad×K-1×m-1 and 0.2 rad×K-1×m-1), at a wavelength of 1550 nm. The fiber features a sufficiently uniform birefringence over its entire length (2.17×10-4 ± 7.65×10-6) and low propagation loss (∼3 dB/km), which allows envisaging pressure measurements along distances up to several kilometers.

5.
Sensors (Basel) ; 22(15)2022 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-35957394

RESUMO

We report on a near-infrared imaging spectrometer for sensing the three most prominent greenhouse gases in the atmosphere (water vapor, carbon dioxide and methane). The optical design of the spectrometer involves freeform optics, which enables achieving exceptional performance and allows progressing well beyond the state-of-the-art in terms of compactness, field-of-view, and spatial resolution. The spectrometer is intended to be launched on a small satellite orbiting at 700 km and observing the Earth with a wide field-of-view of 120° and a spatial resolution of 2.6 km at nadir. The satellite will ultimately allow for improved climate change monitoring.

6.
Opt Express ; 30(7): 12026-12038, 2022 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-35473132

RESUMO

Optical fibers provide a favorable medium for nonlinear optical processes owing to the small mode field size and concurrently high optical intensity combined with the extended interaction lengths. Second harmonic generation (SHG) is one of those processes that has been demonstrated in silica glass optical fibers. Since silica is centrosymmetric, generating SHG in an optical fiber requires poling of the glass. In addition and when one wants to use ultrashort pulses for SHG, achieving both phase and group velocity matching is crucial. Although fibers that feature either modal phase velocity or group velocity matching for SHG have been reported, the possibility of simultaneous modal phase and group velocity matching was never reported before. In this paper we address this challenge, and for the first time to our knowledge, we show that it is feasible to do so with silica microstructured optical fibers featuring at least one ring of air holes in the cladding and a heavily Germanium doped core (above 25 mol.%) by exploiting the LP01(ω) and LP02(2ω) modes at 1.06 µm pump and 0.53 µm second harmonic wavelengths. This finding can greatly impact applications requiring waveguide based SHG generation with ultrashort pulses, including microscopy, material characterization and nonlinear imaging.

7.
Sensors (Basel) ; 21(13)2021 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-34209602

RESUMO

The measurement of the Earth's Outgoing Longwave Radiation plays a key role in climate change monitoring. This measurement requires a compact wide-field-of-view camera, covering the 8-14 µm wavelength range, which is not commercially available. Therefore, we present a novel thermal wide-field-of-view camera optimized for space applications, featuring a field of view of 140° to image the Earth from limb to limb, while enabling a high spatial resolution of 4.455 km at nadir. Our cost-effective design comprises three germanium lenses, of which only one has a single aspherical surface. It delivers a very good image quality, as shown by the nearly-diffraction-limited performance. Radiative transfer simulations indicate excellent performance of our camera design, enabling an estimate of the broadband Outgoing Longwave Radiation with a random relative error of 4.8%.


Assuntos
Mudança Climática , Planeta Terra , Ondas de Rádio
8.
Materials (Basel) ; 14(8)2021 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-33920842

RESUMO

The limited penetration depth of visible light in biological tissues has encouraged researchers to develop novel implantable light-guiding devices. Optical fibers and waveguides that are made from biocompatible and biodegradable materials offer a straightforward but effective approach to overcome this issue. In the last decade, various optically transparent biomaterials, as well as different fabrication techniques, have been investigated for this purpose, and in view of obtaining fully fledged optical fibers. This article reviews the state-of-the-art in the development of biocompatible and biodegradable optical fibers. Whilst several reviews that focus on the chemical properties of the biomaterials from which these optical waveguides can be made have been published, a systematic review about the actual optical fibers made from these materials and the different fabrication processes is not available yet. This prompted us to investigate the essential properties of these biomaterials, in view of fabricating optical fibers, and in particular to look into the issues related to fabrication techniques, and also to discuss the challenges in the use and operation of these optical fibers. We close our review with a summary and an outline of the applications that may benefit from these novel optical waveguides.

9.
Sensors (Basel) ; 21(7)2021 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-33807201

RESUMO

In this study, silica glass, optical fiber Bragg gratings (FBGs) are used for torque-induced strain monitoring in carbon fiber reinforced polymer (CFRP) hollow shafts toward the development of a methodology for structural load monitoring. Optical fibers with gratings are embedded during shaft manufacturing, by an industrial filament winding process, along different orientations with respect to its central axis and surface mounted after production. Experimental results are supported by numerical modeling of the shaft with appropriate boundary conditions and homogenized material properties. For an applied torque up to 800 Nm, the strain sensitivity of an embedded grating positioned along the reinforcing fibers' direction winded under 55° is in the order of 3.6 pm/Nm, while this value is more than 4× times higher than the other examined orientations. The study also shows that surface-mounted optical fiber Bragg gratings along the reinforcing carbon fibers' direction perform equally well in monitoring strains in composite shafts under torque.

10.
Sensors (Basel) ; 20(22)2020 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-33213032

RESUMO

Ultrasonic guided wave (UGW) detection with fiber Bragg grating (FBG)-based sensors has received increasing attention in the last decades due to the ability to perform non-destructive inspection (NDI) of large plate-like surfaces with a network of lightweight and multiplexed sensors. For accurate UGW measurements, several studies concluded that the ratio between the wavelength of the UGW and the length of the FBG should be above 7. However, shorter FBGs suffer from a lower FBG reflectivity and less steep slopes in the reflection spectrum. In this work we experimentally verified the effect of a passing UGW on the Bragg peak of FBG sensors of different lengths. By performing edge-filtering interrogation throughout the FBG's reflection spectrum, we were able to reconstruct the FBG's spectral response to a UGW in function of time. Our experimental findings are partially in line with those in the literature considering the UGW wavelength to FBG length ratio and the corresponding Bragg peak changes. We experimentally show for the first time that for shorter FBG sensors, the strain modulation is translated mostly into Bragg peak shifting, while for longer FBG sensors, Bragg peak deformation takes over as main mechanism. Despite the different mechanism for the latter, the UGW can still be detected by edge-filtering on the steepest slope, and with a much higher sensitivity.

11.
Opt Express ; 27(4): 5487-5501, 2019 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-30876151

RESUMO

The influence of hydrogen gas on Fiber Bragg Grating (FBG)-based optical fiber sensors has been validated experimentally. More in particular, the focus was on FBGs written in the so-called Butterfly Micro Structured Fiber that targets simultaneous pressure and temperature monitoring with a minimum in cross-sensitivity to be used in, for example, downhole applications for the oil and gas market. The hydrogen-induced pressure and temperature errors from this type of sensor have been quantified as a function of the partial hydrogen pressure. The induced errors can be related to the diffusion of the hydrogen into the microstructure and to refractive index changes due to the presence of the hydrogen in the micro holes and penetration of it into the fiberglass. Furthermore, we have also shown that the hydrogen-induced errors scale with the partial hydrogen pressure.

12.
Opt Express ; 26(11): 14741-14751, 2018 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-29877410

RESUMO

Fiber Bragg grating inscription with infrared femtosecond pulsed lasers in photonic crystal fiber is far from being trivial due to the presence of air holes in the cladding region and the non-linear nature of the absorption process inducing the required refractive index changes. We have studied this problem numerically and experimentally for a phase mask-based writing setup equipped with short focal length cylindrical lenses, which are often used for through-coating and high temperature stable grating writing. We have shown that for a cylindrical lens with a focal length f of 10 mm, the hexagonal lattice PCF needs to be translated away from the beam waist position by around 15 µm to efficiently deliver the energy to the core region. We have also investigated the importance of the PCF's angular orientation and we have shown that for some optimal positions the same behavior is observed for cylindrical lenses with different focal lengths. Finally, we have succeeded in writing a 4 dB strong grating in a photonic crystal fiber with a 1030 nm femtosecond pulsed laser in around 4 seconds, using an acylindrical lens with f = 10 mm.

13.
Sci Rep ; 8(1): 5470, 2018 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-29615768

RESUMO

It is common belief that photonic crystals behave similarly to isotropic and transparent media only when their feature sizes are much smaller than the wavelength of light. Here, we counter that belief and we report on photonic crystals that are transparent for anomalously high normalized frequencies up to 0.9, where the crystal's feature sizes are comparable with the free space wavelength. Using traditional photonic band theory, we demonstrate that the isofrequency curves can be circular in the region above the first stop band for triangular lattice photonic crystals. In addition, by simulating how efficiently a tightly focused Gaussian beam propagates through the photonic crystal slab, we judge on the photonic crystal's transparency rather than on isotropy only. Using this approach, we identified a wide range of photonic crystal parameters that provide anomalous transparency. Our findings indicate the possibility to scale up the features of photonic crystals and to extend their operational wavelength range for applications including optical cloaking and graded index guiding. We applied our result in the domain of femtosecond laser micromachining, by demonstrating what we believe to be the first point-by-point grating inscribed in a multi-ring photonic crystal fiber.

14.
Opt Express ; 25(15): 17936-17947, 2017 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-28789282

RESUMO

In this paper, we evaluate different thermal treatments in order to stabilize fiber Bragg gratings written by a femtosecond pulsed laser in specialty highly birefringent micro-structured optical fiber, targeting pressure monitoring at high pressure and high temperature environments. We have obtained a pressure sensitivity of 3.30 pm/bar up to 1400 bar and 290 °C. An effective thermal treatment has been experimentally implemented, yielding a nearly unchanged reflectivity at high temperature in combination with stable temperature and pressure readings: a standard deviation of 0.42 bar in the pressure reading was observed over 7 days at 280°C.

15.
Sensors (Basel) ; 17(9)2017 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-28837066

RESUMO

Conventional contact sensors used for Lamb wave-based ultrasonic inspection, such as piezo-electric transducers, measure omnidirectional strain and do not allow distinguishing between fundamental symmetric and anti-symmetric modes. In this paper, we show that the use of a single fibre Bragg grating created in a dedicated microstructured optical fibre allows one to directly make the distinction between these fundamental Lamb wave modes. This feature stems from the different sensitivities of the microstructured fibre to axial and transverse strain. We fabricated carbon fibre-reinforced polymer panels equipped with embedded microstructured optical fibre sensors and experimentally demonstrated the strain waves associated with the propagating Lamb waves in both the axial and transverse directions of the optical fibre.

16.
Sensors (Basel) ; 16(4)2016 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-27110782

RESUMO

Excessive fuel assembly vibrations in nuclear reactor cores should be avoided in order not to compromise the lifetime of the assembly and in order to prevent the occurrence of safety hazards. This issue is particularly relevant to new reactor designs that use liquid metal coolants, such as, for example, a molten lead-bismuth eutectic. The flow of molten heavy metal around and through the fuel assembly may cause the latter to vibrate and hence suffer degradation as a result of, for example, fretting wear or mechanical fatigue. In this paper, we demonstrate the use of optical fiber sensors to measure the fuel assembly vibration in a lead-bismuth eutectic cooled installation which can be used as input to assess vibration-related safety hazards. We show that the vibration characteristics of the fuel pins in the fuel assembly can be experimentally determined with minimal intrusiveness and with high precision owing to the small dimensions and properties of the sensors. In particular, we were able to record local strain level differences of about 0.2 µÏµ allowing us to reliably estimate the vibration amplitudes and modal parameters of the fuel assembly based on optical fiber sensor readings during different stages of the operation of the facility, including the onset of the coolant circulation and steady-state operation.

17.
Opt Express ; 23(15): 18943-54, 2015 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-26367557

RESUMO

We discuss two algorithms to determine the value and the radial profile of the photoelastic coefficient C in glass and polymer optical fibers. We conclude that C is constant over the fiber cross-sections, with exception of silica glass fibers containing a fluorine-doped depressed cladding. In the undoped and Ge-doped parts of these silica glass fibers we find a consistent value for C that is slightly larger than in bulk silica. In the fluorine-doped trenches of the absolute value of C decreases with about 27%. In polymethyl methacrylate optical fibers, the value of C significantly varies from fiber to fiber.

18.
Sensors (Basel) ; 15(5): 10852-71, 2015 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-25961383

RESUMO

Quality of embedment of optical fibre sensors in carbon fibre-reinforced polymers plays an important role in the resultant properties of the composite, as well as for the correct monitoring of the structure. Therefore, availability of a tool able to check the optical fibre sensor-composite interaction becomes essential. High-resolution 3D X-ray Micro-Computed Tomography, or Micro-CT, is a relatively new non-destructive inspection technique which enables investigations of the internal structure of a sample without actually compromising its integrity. In this work the feasibility of inspecting the position, the orientation and, more generally, the quality of the embedment of an optical fibre sensor in a carbon fibre reinforced laminate at unit cell level have been proven.

19.
Opt Express ; 23(2): 709-23, 2015 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-25835831

RESUMO

During grating inscription in photonic crystal fibers (PCFs) the intensity of the inscribing laser beam is non-uniformly distributed over the core region due to the interaction with the air holes in the fiber's microstructure. In this paper we model and study the non-uniformity of the index modification and its influence on the grating reflection spectra, taking into account the non-linear nature of the index change. For femtosecond laser inscription pulses at 800 nm, we show that the intensity redistribution in the PCF core region can result in Type II index changes even if the peak intensity of the incident beam is well below the corresponding threshold. Our coupled mode analysis reveals that the non-uniform nature of the index change can seriously affect the reflectivity of the grating due to a limited overlap of the guided mode with the transverse index modulation profile for almost all angular orientations of the PCFs with respect to the inscription beam. We also evaluate the influence of PCF tapering and we found that for the considered PCF a significant increase in the induced index change and reflectivity is observed only for taper diameters below 40 µm.

20.
Sensors (Basel) ; 14(12): 24258-77, 2014 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-25521386

RESUMO

The working principle of fiber Bragg grating (FBG) sensors is mostly based on the tracking of the Bragg wavelength shift. To accomplish this task, different algorithms have been proposed, from conventional maximum and centroid detection algorithms to more recently-developed correlation-based techniques. Several studies regarding the performance of these algorithms have been conducted, but they did not take into account spectral distortions, which appear in many practical applications. This paper addresses this issue and analyzes the performance of four different wavelength tracking algorithms (maximum detection, centroid detection, cross-correlation and fast phase-correlation) when applied to distorted FBG spectra used for measuring dynamic loads. Both simulations and experiments are used for the analyses. The dynamic behavior of distorted FBG spectra is simulated using the transfer-matrix approach, and the amount of distortion of the spectra is quantified using dedicated distortion indices. The algorithms are compared in terms of achievable precision and accuracy. To corroborate the simulation results, experiments were conducted using three FBG sensors glued on a steel plate and subjected to a combination of transverse force and vibration loads. The analysis of the results showed that the fast phase-correlation algorithm guarantees the best combination of versatility, precision and accuracy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...